BASF AGRICULTURAL SOLUTIONS US, LLC · Fipronil 80% · EPA Reg 7969-209 · INSECTICIDE; MITICIDE
Document last checked 2025-03-19
According to the label From the product label
These details were extracted from this product's label PDF.
The label is the law.
Confirm every rate, site, restriction and safety requirement against the label before mixing or applying.
Check for a
state supplemental label; a product may be restricted or prohibited in a state or site even when a rate appears below.
·
EPA registration data for Reg. 7969-209 →
Termidor 80 WG is a water-soluble granule formulation used to control subterranean, arboreal, drywood, and dampwood termites, as well as other wood-infesting pests like carpenter ants, beetles, and borers. It is applied outdoors by trenching and rodding around foundations, pillars, and other foundation elements, or by spraying a finished dilution over horizontal surfaces beneath concrete slabs or basements. For vertical treatments, it is applied along the interior and exterior perimeters of foundation walls.
Pests covered (34)
subterranean, arboreal, drywood, and dampwood termites (e.g., Reticulitermes, Coptotermes, Heterotermes, Nasutitermes, and Zootermopsis), and other wood-infesting pests (e.g., carpenter ants, beetles, borers)PILLBUGSCENTIPEDESMILLIPEDESSPIDERSBLACK WIDOW SPIDERBROWN RECLUSE SPIDERDARKLING BEETLESCLUSTER FLYEUROPEAN EARWIGSUBTERRANEAN TERMITESWASPSANTSCARPENTER ANTSARGENTINE ANTPHARAOH ANTCRAZY ANTBIG HEADED ANTSTHIEF ANTODOROUS HOUSE ANTPAVEMENT ANTACROBAT ANTSPAPERNEST WASPSYELLOWJACKETSCARPENTER BEEBOXELDER BUGASIAN LADY BEETLESSILVERFISHBEETLESAUSTRALIAN COCKROACHSMOKY BROWN COCKROACHORIENTAL COCKROACHHOUSE CRICKETBROWN DOG TICK
Areas treatable (20)
foundations deeper than 4 feetConcrete Slab on Ground or in Basements (including Monolithic/Floating/Supported Concrete Slabs) - Horizontal Treated ZonesConcrete Slab on Ground or in Basements (including Monolithic/Floating/Supported Concrete Slabs) - Horizontal treated zones around anything that will penetrate the slab (e.g., utility service, plumbing lines)Concrete Slab on Ground or in Basements (including Monolithic/Floating/Supported Concrete Slabs) - Vertical treated zones along the interior and exterior perimeter of foundation walls and around pillars and other foundation elementsBUILDINGS (NONAGRICULTURAL) (PERIMETER) (SOIL TREATMENT)CONCRETE SLABSCONCRETE SURFACESMASONRYCONCRETE WALLSBASEMENTSDOMESTIC DWELLINGS (INDOOR) (WALL VOIDS)BUILDING FOUNDATIONSWOOD LANDSCAPING MATERIAL (SOIL CONTACT NONFUMIGATION TREATMENT)WOOD FENCE POSTS (SOIL CONTACT NONFUMIGATION TREATMENT)WOOD POLES/POSTS (SOIL CONTACT NONFUMIGATION TREATMENT)WOOD FLOORINGCONCRETE SLABS (SOIL CONTACT NONFUMIGATION TREATMENT)BUILDINGS (EXTERIOR)WOOD SIGNS (SOIL CONTACT NONFUMIGATION TREATMENT)DRAINS
How to treat each type of area 4
foundations deeper than 4 feet
| Target pest |
Location |
Rate |
Unit |
Dilution |
Label notes |
| subterranean, arboreal, drywood, and dampwood termites (e.g., Reticulitermes, Coptotermes, Heterotermes, Nasutitermes, and Zootermopsis), and other wood-infesting pests (e.g., carpenter ants, beetles, borers) |
Outdoor |
2 |
gallons per 10 linear feet per foot of depth |
0.06%, 0.09%, or 0.125% |
When treating foundations deeper than 4 feet, apply Termidor 80 WG finished dilution as the backfill is being replaced, or, if the construction contractor fails to notify the applicator in sufficient time to permit this, treat the foundation to a minimum depth of 4 feet. The applicator must trench and rod into the trench or trench alone along the foundation walls and around pillars and other foundation elements at the rate indicated from grade to a minimum depth of 4 feet. When the top of the footing is exposed, the applicator must treat the soil adjacent to the footing to a depth not to exceed the bottom of the footing. |
Concrete Slab on Ground or in Basements (including Monolithic/Floating/Supported Concrete Slabs) - Horizontal Treated Zones
| Target pest |
Location |
Rate |
Unit |
Dilution |
Label notes |
| subterranean, arboreal, drywood, and dampwood termites (e.g., Reticulitermes, Coptotermes, Heterotermes, Nasutitermes, and Zootermopsis), and other wood-infesting pests (e.g., carpenter ants, beetles, borers) |
Both |
1.0 to 1.5 |
gallons per 10 square feet |
0.06%, 0.09%, or 0.125% |
Apply an overall treatment... to the entire surface that is to be covered beneath the concrete slab. This includes the slab under the actual living area, plus carports, porches, basement floors, and any extended entrances. Make these applications using a coarse application nozzle with a nozzle pressure of 25 PSI or less, spraying the dilution evenly and uniformly over the entire area treated. |
Concrete Slab on Ground or in Basements (including Monolithic/Floating/Supported Concrete Slabs) - Horizontal treated zones around anything that will penetrate the slab (e.g., utility service, plumbing lines)
| Target pest |
Location |
Rate |
Unit |
Dilution |
| subterranean, arboreal, drywood, and dampwood termites (e.g., Reticulitermes, Coptotermes, Heterotermes, Nasutitermes, and Zootermopsis), and other wood-infesting pests (e.g., carpenter ants, beetles, borers) |
Both |
1.0 to 1.5 |
gallons per one square foot |
0.06%, 0.09%, or 0.125% |
Concrete Slab on Ground or in Basements (including Monolithic/Floating/Supported Concrete Slabs) - Vertical treated zones along the interior and exterior perimeter of foundation walls and around pillars and other foundation elements
| Target pest |
Location |
Rate |
Unit |
Dilution |
| subterranean, arboreal, drywood, and dampwood termites (e.g., Reticulitermes, Coptotermes, Heterotermes, Nasutitermes, and Zootermopsis), and other wood-infesting pests (e.g., carpenter ants, beetles, borers) |
Both |
2 |
gallons per 10 linear feet per foot of depth |
0.06%, 0.09%, or 0.125% |
Mixing instructions 8
| Amount |
Per |
Finished strength |
Label notes |
| 1 |
25 gals water |
0.09% |
|
| 2 |
50 gals water |
0.09% |
|
| 4 |
100 gals water |
0.09% |
|
| 1 |
17 gals water |
0.125% |
|
| 2 |
34 gals water |
0.125% |
|
| 4 |
67 gals water |
0.125% |
|
| 6 |
100 gals water |
0.125% |
|
| 2 |
25 gals water |
0.25% |
If soil will not accept labeled volumes... twice the concentration... may be applied in half the volume of finished dilution. |
Use restrictions 4
- DO NOT treat a structure below the bottom of the footing.
- DO NOT apply at a LOWER dosage and/or concentration than 0.06%, 0.09%, or 0.125% for horizontal and vertical treatments.
- DO NOT apply at a LOWER finished dilution volume than 1.0 to 1.5 gallons per 10 square feet for concrete slabs on ground or in basements (horizontal treated zones).
- DO NOT apply at a LOWER finished dilution volume than 2 gallons per 10 linear feet per foot of depth for vertical treated zones along the interior and exterior perimeter of foundation walls and around pillars and other foundation elements.
Active ingredient
Fipronil 80%
Publication withheld. This catalog record has no active evidence summary, so its document and any extracted directions remain unavailable while identity and document role are reviewed.